Submit your IO500 results for the upcoming SC'26 list, which will be presented at our BOF. See the Call for Submissions for details.
Ranking of all valid submissions ever received, including duplicate entries for the same storage system.
| # | BoF | Information | IO500 | Repro. | |||||
|---|---|---|---|---|---|---|---|---|---|
| Institution System · FS Type | Storage Vendor | Client Nodes | Total Client Proc. | Score | BW | MD | |||
| (GiB/s) | (kIOP/s) | ||||||||
| 101 | SC18 | Google Cloud | 60 | 480 | 39.12 | 14.31 | 106.91 | - | |
| 102 | ISC21 | Google Cloud | DDN | 1,000 | 5,000 | 569.99 | 282.78 | 1,148.90 | - |
| 103 | SC19 | Google Cloud | Google Cloud | 200 | 1,600 | 67.78 | 26.93 | 170.61 | - |
| 104 | SC19 | Google Cloud | Google Cloud | 200 | 1,600 | 52.96 | 17.31 | 162.06 | - |
| 105 | SC18 | Google and DDN | 10 | 80 | 12.82 | 4.30 | 38.23 | - | |
| 106 | SC21 | HHMIJRC | Vast Data | 80 | 2,880 | 21.72 | 14.11 | 33.42 | - |
| 107 | ISC19 | Hewlett Packard Enterprise | Hewlett Packard Enterprise | 10 | 200 | 26.21 | 19.57 | 35.11 | - |
| 108 | ISC21 | Howard Hughes Medical Institute Janelia Research Campus | Weka.io | 10 | 300 | 62.68 | 18.17 | 216.22 | - |
| 109 | ISC21 | Howard Hughes Medical Institute Janelia Research Campus | Vast | 10 | 300 | 15.50 | 7.54 | 31.84 | - |
| 110 | SC21 | Huawei Cloud | PDSL | 15 | 1,560 | 2,016.70 | 109.82 | 37,034.00 | - |
| 111 | SC21 | Huawei HPDA Lab | Huawei | 10 | 1,720 | 2,395.03 | 314.56 | 18,235.71 | - |
| 112 | ISC18 | IBM | IBM | 10 | 10 | 24.24 | 4.57 | 128.61 | - |
| 113 | SC21 | IBM Tucson | IBM | 10 | 200 | 68.83 | 33.02 | 143.46 | - |
| 114 | ISC23 | IBM Tuscon | IBM | 10 | 200 | 128.00 | 73.80 | 222.03 | |
| 115 | ISC22 | IBM Tuscon | IBM | 10 | 200 | 110.07 | 62.59 | 193.59 | - |
| 116 | SC21 | IBMDL | IBM | 10 | 0 | 3.17 | 0.61 | 16.57 | - |
| 117 | SC19 | IST Austria | Homemade@IST | 4 | 80 | 8.41 | 1.77 | 39.98 | - |
| 118 | SC19 | IST Austria | Homemade@IST | 10 | 100 | 6.63 | 1.39 | 31.62 | - |
| 119 | ISC23 | Imperial College London | Lenovo | 32 | 512 | 119.56 | 44.63 | 320.31 | |
| 120 | ISC19 | Inspur | Inspur | 10 | 400 | 20.17 | 8.61 | 47.26 | - |
| 121 | ISC19 | Inspur | Inspur | 10 | 400 | 14.67 | 4.48 | 48.06 | - |
| 122 | ISC21 | Intel | Intel | 10 | 1,440 | 1,859.56 | 398.77 | 8,671.65 | - |
| 123 | ISC20 | Intel | Intel | 52 | 1,664 | 1,792.98 | 371.67 | 8,649.57 | - |
| 124 | ISC20 | Intel | Intel | 52 | 1,664 | 1,614.02 | 368.44 | 7,070.51 | - |
| 125 | SC19 | Intel | Intel | 26 | 728 | 933.64 | 183.36 | 4,753.79 | - |
| 126 | ISC20 | Intel | Intel | 10 | 420 | 758.71 | 164.77 | 3,493.56 | - |
| 127 | ISC20 | Intel | Intel | 10 | 420 | 736.33 | 163.19 | 3,322.40 | - |
| 128 | SC19 | Intel | Intel | 10 | 310 | 516.41 | 123.89 | 2,152.46 | - |
| 129 | ISC23 | Intel | Intel | 10 | 1,040 | 431.43 | 125.21 | 1,486.53 | |
| 130 | SC20 | Intel | Intel | 10 | 640 | 353.72 | 43.59 | 2,870.64 | - |
| 131 | ISC23 | Intel | Intel | 10 | 1,120 | 211.34 | 31.00 | 1,440.73 | |
| 132 | ISC19 | JCAHPC | DDN | 2,048 | 2,048 | 275.65 | 492.06 | 154.41 | - |
| 133 | SC20 | JCAHPC | DDN | 2,048 | 4,096 | 253.57 | 697.20 | 92.22 | - |
| 134 | ISC20 | JCAHPC | DDN | 512 | 4,096 | 175.85 | 348.95 | 88.62 | - |
| 135 | ISC20 | JCAHPC | DDN | 2,048 | 16,384 | 168.09 | 581.43 | 48.60 | - |
| 136 | ISC20 | JCAHPC | DDN | 512 | 4,096 | 146.33 | 341.29 | 62.74 | - |
| 137 | ISC18 | JCAHPC | DDN | 2,048 | 16,384 | 137.78 | 560.10 | 33.89 | - |
| 138 | ISC18 | JCAHPC | DDN | 2,048 | 16,384 | 101.48 | 471.25 | 21.85 | - |
| 139 | SC18 | JCAHPC | DDN | 256 | 8,192 | 44.24 | 21.42 | 91.40 | - |
| 140 | SC18 | JCAHPC | DDN | 256 | 8,192 | 42.18 | 20.04 | 88.78 | - |
| 141 | ISC19 | JIHT RAS | 10 | 60 | 3.55 | 0.51 | 24.88 | - | |
| 142 | ISC19 | JIHT RAS | 10 | 320 | 3.19 | 0.51 | 20.03 | - | |
| 143 | ISC20 | JINR | RSC Group | 50 | 800 | 90.87 | 35.61 | 231.88 | - |
| 144 | ISC20 | JINR | RSC Group | 50 | 800 | 88.51 | 36.28 | 215.97 | - |
| 145 | ISC23 | JNIST and HUST PDSL | Huawei | 10 | 9,600 | 137,100.02 | 2,439.37 | 7,705,448.04 | |
| 146 | ISC18 | JSC | ThinkparQ | 8 | 64 | 35.77 | 14.24 | 89.81 | - |
| 147 | SC20 | Janelia Research Campus, HHMI | WekaIO | 48 | 1,248 | 134.09 | 48.03 | 374.40 | - |
| 148 | SC20 | Janelia Research Campus, HHMI | WekaIO | 40 | 1,040 | 123.47 | 43.63 | 349.44 | - |
| 149 | ISC19 | Janelia Research Campus, HHMI | WekaIO | 10 | 3,200 | 66.43 | 27.74 | 159.12 | - |
| 150 | SC20 | Janelia Research Campus, HHMI | WekaIO | 10 | 320 | 57.99 | 20.80 | 161.71 | - |
| 151 | SC19 | Janelia Research Campus, HHMI | WekaIO | 18 | 1,368 | 48.75 | 26.22 | 90.62 | - |
| 152 | SC19 | Janelia Research Campus, HHMI | WekaIO | 10 | 1,440 | 36.55 | 18.58 | 71.90 | - |
| 153 | ISC20 | Janelia Research Campus, HHMI | WekaIO | 10 | 600 | 31.39 | 12.34 | 79.83 | - |
| 154 | ISC20 | Janelia Research Campus, HHMI | WekaIO | 10 | 600 | 30.83 | 13.35 | 71.22 | - |
| 155 | SC19 | Janelia Research Campus, HHMI | WekaIO | 10 | 480 | 25.86 | 7.75 | 86.29 | - |
| 156 | SC19 | Janelia Research Campus, HHMI | WekaIO | 10 | 480 | 25.46 | 7.65 | 84.69 | - |
| 157 | SC19 | Janelia Research Campus, HHMI | WekaIO | 10 | 400 | 24.70 | 16.32 | 37.37 | - |
| 158 | ISC20 | Janelia Research Campus, HHMI | WekaIO | 10 | 600 | 24.19 | 11.85 | 49.39 | - |
| 159 | ISC20 | Janelia Research Campus, HHMI | WekaIO | 10 | 600 | 21.32 | 11.27 | 40.32 | - |
| 160 | SC19 | Janelia Research Campus, HHMI | WekaIO | 10 | 480 | 18.07 | 7.75 | 42.12 | - |
| 161 | ISC19 | Janelia Research Campus, HHMI | Vast Data | 96 | 3,072 | 17.18 | 8.15 | 36.22 | - |
| 162 | SC19 | Janelia Research Campus, HHMI | Vast Data | 88 | 2,816 | 12.50 | 8.31 | 18.79 | - |
| 163 | ISC19 | Janelia Research Campus, HHMI | 96 | 960 | 12.45 | 3.22 | 48.16 | - | |
| 164 | ISC19 | Janelia Research Campus, HHMI | Vast Data | 10 | 480 | 11.96 | 5.64 | 25.37 | - |
| 165 | SC20 | Janelia Research Campus, HHMI | Vast Data | 10 | 260 | 10.64 | 7.44 | 15.22 | - |
| 166 | ISC20 | Janelia Research Campus, HHMI | Vast Data | 10 | 620 | 9.87 | 6.36 | 15.32 | - |
| 167 | ISC19 | Janelia Research Campus, HHMI | 10 | 320 | 9.22 | 2.38 | 35.64 | - | |
| 168 | SC19 | Janelia Research Campus, HHMI | Vast Data | 10 | 480 | 8.45 | 6.16 | 11.60 | - |
| 169 | SC19 | Janelia Research Campus, HHMI | Vast Data | 10 | 820 | 8.01 | 6.31 | 10.17 | - |
| 170 | SC19 | Janelia Research Campus, HHMI | Vast Data | 10 | 480 | 7.77 | 5.39 | 11.18 | - |
| 171 | ISC20 | Janelia Research Campus, HHMI | Vast Data | 10 | 620 | 7.27 | 5.96 | 8.86 | - |
| 172 | SC19 | Janelia Research Campus, HHMI | #N/A | 10 | 760 | 6.42 | 2.61 | 15.82 | - |
| 173 | ISC20 | Janelia Research Campus, HHMI | Vast Data | 10 | 620 | 6.20 | 3.51 | 10.95 | - |
| 174 | ISC19 | Janelia Research Campus, HHMI | Qumulo | 10 | 320 | 5.95 | 2.59 | 13.69 | - |
| 175 | ISC20 | Janelia Research Campus, HHMI | Vast Data | 10 | 620 | 5.68 | 3.67 | 8.80 | - |
| 176 | ISC19 | Janelia Research Campus, HHMI | Qumulo | 96 | 960 | 5.32 | 2.80 | 10.11 | - |
| 177 | ISC20 | Janelia Research Campus, HHMI | Vast Data | 10 | 620 | 4.98 | 3.56 | 6.96 | - |
| 178 | ISC19 | Janelia Research Campus, HHMI | Qumulo | 10 | 120 | 4.46 | 2.12 | 9.35 | - |
| 179 | SC19 | Janelia Research Campus, HHMI | Qumulo | 10 | 760 | 4.19 | 2.88 | 6.11 | - |
| 180 | SC19 | Janelia Research Campus, HHMI | Qumulo | 10 | 760 | 3.67 | 2.45 | 5.49 | - |
| 181 | ISC21 | Japan Agency for Marine-Earth Science and Technology | DDN | 10 | 320 | 101.88 | 48.19 | 215.38 | - |
| 182 | SC20 | Johannes Gutenberg University Mainz | JGU (ADA-FS)& BSC (NEXTGenIO) | 10 | 240 | 167.64 | 22.97 | 1,223.59 | - |
| 183 | ISC20 | Johannes Gutenberg University Mainz | JGU (ADA-FS)& BSC (NEXTGenIO) | 10 | 160 | 96.46 | 11.61 | 801.60 | - |
| 184 | ISC20 | Johannes Gutenberg University Mainz | JGU (ADA-FS)& BSC (NEXTGenIO) | 10 | 160 | 92.91 | 10.96 | 787.71 | - |
| 185 | ISC18 | Joint Institute for Nuclear Research | RSC | 24 | 192 | 12.08 | 3.34 | 43.65 | - |
| 186 | ISC21 | Joint Institute of Nuclear Research | RSC | 10 | 160 | 132.07 | 20.19 | 863.69 | - |
| 187 | SC20 | Joint Supercomputer Center of the Russian Academy of Sciences | RSC Group | 54 | 864 | 125.50 | 45.31 | 347.61 | - |
| 188 | ISC18 | KAUST | Cray | 1,024 | 8,192 | 77.37 | 496.81 | 12.05 | - |
| 189 | ISC18 | KAUST | Cray | 300 | 2,400 | 70.90 | 151.53 | 33.17 | - |
| 190 | ISC18 | KAUST | Cray | 1,000 | 16,000 | 41.00 | 54.17 | 31.03 | - |
| 191 | SC18 | KAUST | Cray | 10 | 80 | 13.99 | 14.45 | 13.53 | - |
| 192 | ISC20 | Korea Institute of Science and Technology Information (KISTI) | DDN | 2,048 | 2,048 | 282.45 | 515.59 | 154.74 | - |
| 193 | SC18 | Korea Institute of Science and Technology Information (KISTI) | DDN | 2,048 | 4,096 | 156.91 | 554.23 | 44.43 | - |
| 194 | SC18 | Korea Institute of Science and Technology Information (KISTI) | DDN | 2,048 | 4,096 | 35.97 | 14.06 | 92.03 | - |
| 195 | ISC20 | LNCC | Cay/HPE | 10 | 240 | 3.06 | 2.32 | 4.02 | - |
| 196 | ISC23 | LRZ | Lenovo | 24 | 2,688 | 2,111.06 | 433.05 | 10,291.12 | |
| 197 | ISC23 | LRZ | Lenovo | 10 | 1,120 | 1,533.28 | 266.73 | 8,813.96 | |
| 198 | ISC23 | LRZ | Lenovo | 24 | 2,688 | 1,386.41 | 336.35 | 5,714.63 | |
| 199 | ISC22 | LRZ | Lenovo | 20 | 1,280 | 1,371.30 | 321.75 | 5,844.40 | - |
| 200 | ISC22 | LRZ | Lenovo | 10 | 640 | 1,034.55 | 209.48 | 5,109.23 | - |
Top 10 systems compared
Each axis is scaled to the highest value among these systems — 100% marks the leader on that dimension. Click a system below to toggle it.
- #101 Exascaler-on-GCP Google
- #102 Google Google Cloud
- #103 EXA5-GCP-PD-SSD Google Cloud
- #104 EXA5-GCP-PD-STD Google Cloud
- #105 Lustre on GCP Google and DDN
- #106 Janelia Compute Cluster HHMIJRC
- #107 GTO Hewlett Packard Enterprise
- #108 Janelia Howard Hughes Medical Institute Janelia Research Campus
- #109 Howard Hughes Medical Institute Janelia Research Campus
- #110 Huawei Cloud