Submit your IO500 results for the upcoming SC'26 list, which will be presented at our BOF. See the Call for Submissions for details.
This is the official list from Supercomputing 2019. The list shows the best result for a given combination of system/institution/filesystem.
Please see also the 10 node challenge ranked list.
| # | BoF | Information | IO500 | Repro. | |||||
|---|---|---|---|---|---|---|---|---|---|
| Institution System · FS Type | Storage Vendor | Client Nodes | Total Client Proc. | Score | BW | MD | |||
| (GiB/s) | (kIOP/s) | ||||||||
| 1 | SC19 | National Supercomputing Center in Changsha | National University of Defense Technology | 480 | 5,280 | 453.68 | 209.43 | 982.78 | - |
| 2 | SC19 | WekaIO | WekaIO | 345 | 8,625 | 938.95 | 174.74 | 5,045.33 | - |
| 3 | SC19 | Google Cloud | Google Cloud | 200 | 1,600 | 67.78 | 26.93 | 170.61 | - |
| 4 | SC19 | Google Cloud | Google Cloud | 200 | 1,600 | 52.96 | 17.31 | 162.06 | - |
| 5 | SC19 | University of Cambridge | Dell EMC | 128 | 2,048 | 229.45 | 131.25 | 401.13 | - |
| 6 | SC19 | CEA | DDN | 128 | 4,096 | 210.26 | 81.01 | 545.74 | - |
| 7 | SC19 | CNES | DDN | 96 | 96 | 34.76 | 8.51 | 141.99 | - |
| 8 | SC19 | Janelia Research Campus, HHMI | Vast Data | 88 | 2,816 | 12.50 | 8.31 | 18.79 | - |
| 9 | SC19 | Oracle Cloud Infrastructure | Oracle Cloud Infrastructure Block Volumes Service | 30 | 480 | 47.55 | 20.38 | 110.93 | - |
| 10 | SC19 | Intel | Intel | 26 | 728 | 933.64 | 183.36 | 4,753.79 | - |
| 11 | SC19 | CSIRO | Dell/ThinkParQ | 26 | 260 | 94.86 | 69.10 | 130.23 | - |
| 12 | SC19 | Janelia Research Campus, HHMI | WekaIO | 18 | 1,368 | 48.75 | 26.22 | 90.62 | - |
| 13 | SC19 | SUSE | SUSE, Intel, Lenovo | 15 | 120 | 14.91 | 5.74 | 38.72 | - |
| 14 | SC19 | NVIDIA | DDN | 10 | 400 | 249.50 | 86.97 | 715.76 | - |
| 15 | SC19 | State Key Laboratory of High-end Server & Storage Technology (HSS) | INSPUR | 10 | 300 | 82.57 | 41.14 | 165.71 | - |
| 16 | SC19 | DDN | DDN | 10 | 240 | 63.88 | 19.65 | 207.63 | - |
| 17 | SC19 | Penguin Computing Benchmarking and Innovation Lab | Penguin Computing/Excelero | 10 | 320 | 39.65 | 17.71 | 88.76 | - |
| 18 | SC19 | Clemson University | AdvancedHPC | 10 | 120 | 21.55 | 12.97 | 35.80 | - |
| 19 | SC19 | Stanford | Dell | 10 | 160 | 7.05 | 1.64 | 30.28 | - |
| 20 | SC19 | Janelia Research Campus, HHMI | #N/A | 10 | 760 | 6.42 | 2.61 | 15.82 | - |
| 21 | SC19 | Janelia Research Campus, HHMI | Qumulo | 10 | 760 | 4.19 | 2.88 | 6.11 | - |
| 22 | SC19 | Janelia Research Campus, HHMI | Qumulo | 10 | 760 | 3.67 | 2.45 | 5.49 | - |
Top 10 systems compared
Each axis is scaled to the highest value among these systems — 100% marks the leader on that dimension. Click a system below to toggle it.
- #1 Tianhe-2E National Supercomputing Center in Changsha
- #2 WekaIO on AWS WekaIO
- #3 EXA5-GCP-PD-SSD Google Cloud
- #4 EXA5-GCP-PD-STD Google Cloud
- #5 Data Accelerator University of Cambridge
- #6 Tera-1000 CEA
- #7 HAL CNES
- #8 Vast Janelia Research Campus, HHMI
- #9 Oracle Cloud Infrastructure with Block Volume Service running Spectrum Scale Oracle Cloud Infrastructure
- #10 Wolf Intel