HiPerGator
University of Florida · DDN Blue · Fully Reproducible
System Purpose
Question asked
Please describe the purpose and general usage of the submitted system. This would include the types of typical applications it supports (e.g., defense applications, molecular dynamics, benchmarking, system test, systems research), and the general use and purpose of the data generated by the applications running on it.
HiPerGator is the centralized research computing platform for the University of Florida. HiPerGator supports all manner of research activities at the University, and is a teaching platform, as well. HiPerGator's Blue storage system is the primary storage of the system - use for Slurm job I/O, project storage, conda environments, etc. The applications run on the system is very diverse, ranging from custom, community, and commercial applications and frameworks supporting AI topics including training of large language models and generative AI, to molecular dynamics, computational fluid dynamics, image processing, quantum chemistry, astronomy, and more. The data on the system includes (but is not limited to) text and image training inputs including data containing protected health informantion and associated outputs, simulation and visualization tool outputs, databases, and more. HiPerGator and its Blue storage system provides researchers, educators, and students with a single platform to meet cutting edge research needs, as well as those needed to train a workforce that is AI-aware.
Availability
Question asked
Please provide the deployment timeframe of the submitted system, or for on-demand cloud systems, the general period over which it is deployed and destroyed.
Please describe the availability of the system to users and who are its set of most regular users.
HiPerGator's 4th Generation compute nodes from Lenovo were delivered in May 2025 and the Blue storage system was delivered in July 2025. The compute systems entered production general availability in June 2025. The system was benchmarked and entered production general availability in Oct 2025. The users of the combined system span a very broad array of research disciplines, but if I have to pick who are the most regular users, I would have to choose those in the fields of Chemistry (molecular dynamics), Astronomy, and Medical sciences.
Storage System Software
Question asked
How is this storage software available? (e.g., commercially, open-source, not publicly available) Note that if the storage software is not open-source or commercially available, then a general description would be requested, but this would limit the submission’s reproducibility score.
Can anyone download/purchase this software?
List either product webpage or open-source repo of the exact software used in IO500.
Give any and all additional details of this specific storage deployment: (e.g., type of storage server product such IBM ESS or DDN SFA400X2, use of Ext4 or some other file system on each storage node, dual connected storage media to storage servers).
The Blue storage system software is DDN EXAScaler, which is a commercially-supported product built on the open-source Lustre filesystem. The product webpage can be found here: https://www.ddn.com/products/lustre-file-system-exascaler/ . I believe anyone can purchase this software and support. Lustre itself is available as open-source software here: https://www.lustre.org/
The Blue storage system is composed two ES400X3 appliances dedicated for metadata, and three ES400NVX2 appliances dedicated to data object storage.
Each ES400X3 appliance provides 2 virtual metadata servers (MDS), each with two metadata targets (MDTs). Each ES400NVX2 appliance provides 4 virtual object storage servers (OSS) that each have 2 object storage targets (OSTs). All of the servers and storage targets are highly available. Each MDS has two NDR400 InfiniBand interfaces, and each OSS has two NDR200 InfiniBand interfaces. All are connected to a two layer (spine-leaf) InfiniBand fabric that is used both for message passing and storage access.
The Blue storage system takes advantage of the following Lustre features - project quota, distributed namespace (DNE), progressive file layout (PFL), multi-rail LNet, and dynamic LNet configuration (on clients).
Runtime Environment
Question asked
State here that you provided all scripts/documentation that would allow someone else to reproduce your environment and attempt to achieve a similar IO500 score as the submitted system.
NOTE: provide all files/documentation/scripts that would enable a user to build your environment and deploy the custom scripts, software, or config files once they have obtained the appropriate storage system hardware and software. These may be included into the io500.tgz or into the extraCodes upload on the submission form.
Several examples include:
- Commands used to set striping information (either for the entire system or for particular directories)
- File system config and tuning information (or a reason why this is not available due to lack of root access, etc) on each node type (e.g., non-default config parameters on all three types of Lustre nodes: MDS, OSS, and client)
- Any additional scripts utilized that impact IO500 execution beyond the io500 config file. For example, with IBM Spectrum Scale, the output of mmlsconfig, mmlscluster, mmlsfs, and mmlsfileset commands (and possibly even a dump of the configuration if possible). Each file system probably has similar type of config/tuning information that would need to be shared for a user to fully reproduce the environment.
The script to run io500 is included in this submission along with its stdout/stderr, and the full io500 output tarball. In this submission, openmpi v5.0.7 was used, compiled with gcc 14.2.0. The io500-10x192-blue2-24mount-turin-smt.sh script's setup() function contains the directory creation and layout paramters used. On the Lenovo SR635v3 clients, SMT is enabled.
In this submission, we use 24 mounts of the same filesystem on each client host, each at a different mountpoint, and invoke io500 via a container. This allows for additional scalability vs a single mountpoint per client.
The individual mountpoints are bind-mounted into the containers to the same directory; thus each container can access the filesystem via different mountpoints on the underlying client host. The container image used in this submission is for Rocky Linux v9. The image was pulled with apptainer and saved as a sif file with this command:apptainer pull docker://rockylinux:9
In io500-10x192-blue2-24mount-turin-smt.sh, there is a helper script to set up the container bind mounts based upon MPI rank referenced in the mpiargs variable, which is not included in the tarball (apptainer-stripe-over-nodes-numanodes-stripe-mounts-over-ranks.sh). The contents of this script are:
#!/bin/sh
ARGV=($*)
NUMANODES_PER_HOST=${ARGV[0]}
PHYSCORES_PER_NUMANODE=${ARGV[1]}
NUM_MOUNTPOINTS=${ARGV[2]}
FS=${ARGV[3]}
unset ARGV[3]
unset ARGV[2]
unset ARGV[1]
unset ARGV[0]
# Rotate over NUM_MOUNTPOINTS by local rank
MNT_ID=$((OMPI_COMM_WORLD_LOCAL_RANK % NUM_MOUNTPOINTS))
# Distribute ranks evenly across NUMA nodes
NUMANODE=$((OMPI_COMM_WORLD_LOCAL_RANK % NUMANODES_PER_HOST))
RANK_WITHIN_NUMANODE=$((OMPI_COMM_WORLD_LOCAL_RANK / NUMANODES_PER_HOST))
HWT=$(( (NUMANODE * PHYSCORES_PER_NUMANODE) + RANK_WITHIN_NUMANODE ))
# If SMT/HT is turned on
if [ ${RANK_WITHIN_NUMANODE} -ge ${PHYSCORES_PER_NUMANODE} ] ; then
HWT=$(( (NUMANODES_PER_HOST * PHYSCORES_PER_NUMANODE) + (NUMANODE * PHYSCORES_PER_NUMANODE) + (RANK_WITHIN_NUMANODE % PHYSCORES_PER_NUMANODE) ))
fi
NUMACTL="numactl --membind=${NUMANODE} --physcpubind=${HWT}"
${NUMACTL} apptainer exec --bind /${FS}_${MNT_ID}:/mnt ${ARGV[*]}
On servers, the following settings are in place for production use, and were not changed for the benchmark (some of these may replicate default values), from exascaler.toml:
[host_defaults.modprobe_cfg.ko2iblnd]
ntx = 5120
peer_credits = 42
peer_credits_hiw = 21
concurrent_sends = 84
credits = 2560
ib_mtu = 4096
fmr_pool_size = 1280
fmr_flush_trigger = 1024
[host_defaults.modprobe_cfg.mdt]
max_mod_rpcs_per_client = 128
[set_param_tunings]
'llite.blue2-*.max_read_ahead_mb' = 2048
'llite.blue2-*.max_read_ahead_per_file_mb' = 256
'llite.blue2-*.max_read_ahead_whole_mb' = 64
'osc.blue2-*.max_pages_per_rpc' = "1M"
'osc.blue2-*.max_dirty_mb' = 2048
'osc.blue2-*.max_rpcs_in_flight' = 128
'osc.blue2-*.checksum_type' = "crc32c"
'osc.blue2-*.checksums' = 1
'osd-ldiskfs.blue2-*.writethrough_cache_enable' = 0
'osd-ldiskfs.blue2-*.read_cache_enable' = 0
'obdfilter.blue2-*.brw_size' = 16
'obdfilter.blue2-*.precreate_batch' = 1024
'mdd.blue2*.atime_diff' = 86400
'mdc.blue2-*.max_rpcs_in_flight' = 128
'mdc.blue2-*.max_mod_rpcs_in_flight' = 127
I believe the above notes will allow anyone to reproduce the submitted result with the same equipment and network configuration.
Fault Tolerance Mechanisms
Question asked
Does your system have a single point of failure as defined by “Definition 7” of a Production System? Please describe all mechanisms that provide fault tolerance for the submitted storage system. Be specific to your submission, not general storage system capabilities.
- Power (For example, can power failure of a node or rack bring down the storage system?)
- Networking (For example, can failure of a single NIC bring down the storage system? Remember that any networking failure that brings down multiple nodes is acceptable)
- Inter storage data and metadata server (For example, what type of data protection mechanism does the storage system use to keep operating during node failures, e.g., active-active servers, client-directed RAID, declustered RAID, erasure-coding, 3-way replication)
- Intra storage data and metadata server storage media (For example, how does the storage eysstem protect against fiailure of a single storage device within a node, e.g., raid5)
Please list any additional information needed to determine whether this system has a single point of failure.
The storage system does not have a single point of failure as defined by definition 7 of a Production System:
- All storage appliances have dual PSUs connected to different rack PDUs
- All rack PDUs are connected to a fault tolerant power distribution system in the data center, backed by a UPS and a generator
- All virtual storage servers are dual-connected to different IB switches using different NICs - loss of a single switch or NIC anywhere will not disrupt access to the storage system.
- Virtual storage server failures are handled by high-availability software (corosync and pacemaker). In the event of a virtual storage server failure, the failure will be detected and the storage and services running on it will be migrated to other virtual storage servers.
- All appliances have two controllers - in the event one fails, services from down virtual storage servers will move to HA partners and the other controller will take over IOs
- The drives in each ES400NVX2 appliance are configured as a single declustered RAID pool, with 8 virtual disks created upon that pool. The VDs are each configured with double-parity protection (RAID6). The pool configuration reserves capacity on the pool to allow for rebuilds to begin immediately in the event of a drive failure (does not need to wait for drive replacement).
- The drives in each ES400X3 appliance are configured as two DCR pools, each with 2 virtual disks. The VDs are each configured with double-parity protection (RAID6).
Execution
Question asked
Please provide a description of how the IO500 benchmark was executed, e.g., via system scheduler (e.g., SLURM) to run a job on the compute cluster, which initially ran a setup process to configure the client and file system, and then started the full benchmark.
During the IO500 benchmark execution was the system entirely dedicated to running the benchmark or were there other jobs running in the same cluster and storage system?
The io500 benchmark was executed interactively on 10 client nodes offline for FW and OS upgrade while the rest of the system was in regular production, though running via a SLURM batch job should produce the same result. The system was not dedicated to running the benchmark, numerous other jobs were observed to be running on the system while the benchmark was run.
Caching
Question asked
Please describe all caching mechanisms in client/server that were utilized during the IO500 run. This could include caching in any storage medium (e.g., SSD, RAM).
A few examples would include:
- Client data/metadata caching (in Linux page cache or in other memory cache)
- Client side NVMe read-only data cache
- Storage server metadata/data caching in RAM
- Storage controller caching
- RAID card caching
- O_DIRECT was used for any tests that allowed it (or would even work due to req PAGE_SIZE alignment), skipping the client side page cache
- inode_cache=0 was set on all clients
- Client side NVMe read-only data cache was not configured or used.
- Lustre server side bypasses the server side caches when using non-rotational media. In addition, virtual storage server settings writethrough_cache_enable and read_cache_enable settings were disabled, as is normal for this system in production.
- Lustre servers do have an ldiskfs inode cache
- Lustre clients have a client side page cache that is integral to the filesystem, but it's POSIX compliant
Storage controller caching was enabled on the virtual disks as follows:
Cache Settings:
ReACT: TRUE
Read Ahead: FALSE
Write Back: TRUE
Mirroring: TRUE
Data Source
Question asked
Is the submitted system a stand-alone storage system or an acceleration layer in front of another storage system that is the source of truth for all application data? This question relates to whether the submitted system is a burst buffer layered on primary storage or primary storage itself.
The system is a stand-alone storage system. It is not a burst buffer layered on primary storage. All clients natively mount the storage as Lustre.
Trust
Question asked
Please describe any steps taken to ensure that the results are trustworthy.
- Did you run the benchmark multiple times and get similar scores?
- Did you validate the score is below the physical capabilities of the deployed hardware?
- How did you validate that the storage system follows the IO500 rules regarding persistence, which states, "All data must be written to persistent storage within the measured time for the individual benchmark, e.g. if a file system caches data, it must ensure that data is persistently stored before acknowledging the close"?
The benchmark was run many times with little variation in the scores. In addition, using 12 mounts per client produced a very similar score.
I used the datasheets of the appliances in our system to ascertain the maximum throughputs possible in reads and writes. I was able to reach the published maximum throughput of the system in writes, and very close to the published maximum for reads using 10 clients with ior-easy.
The storage system is a POSIX-compliant, cache-coherent parallel filesystem with global lock management and flock enabled. I did not verify persistence personally, but the Lustre filesystem is known to comply with io500 rules regarding persistence.